[AGENT++] "cmd_exe_mib" example project
Frank Fock
fock at agentpp.com
Thu Oct 30 18:07:03 CET 2014
Hi,
Why do you think that it is not working for you?
Seems to be working for me. Maybe you expect something different?
Best regards,
Frank
Am 30.10.2014 08:14, schrieb Олег Соковых:
> Hi all!
>
> I'm trying to test "cmd_exe_mib" example project from
> "agent++-4.0.2/examples". But this project isn't working for me.
> After running the command
> "agent++-4.0.2/examples/cmd_exe_mib/src/agent" I see the following:
>
> ==
> 20141028.14:27:11: 00 87 2C
> B7 ..,.
> : (1)EVENT : main: SNMP listen port: (4700)
> 20141028.14:27:11: 00 87 2C
> B7 ..,.
> : (1)DEBUG : TaskManager: thread started
> 20141028.14:27:11: 00 87 2C
> B7 ..,.
> : (1)DEBUG : TaskManager: thread started
> 20141028.14:27:11: 00 87 2C
> B7 ..,.
> : (1)DEBUG : TaskManager: thread started
> 20141028.14:27:11: 00 87 2C
> B7 ..,.
> : (1)DEBUG : TaskManager: thread started
> 20141028.14:27:11: 00 87 2C
> B7 ..,.
> : (1)DEBUG : TaskManager: thread started
> 20141028.14:27:12: 00 87 2C
> B7 ..,.
> : (1)DEBUG : TaskManager: thread started
> ==
>
> With help snmpWalk I see these oid's:
> ==
> OID: .1.3.6.1.2.1.1.1.0
> Value: AGENT++v3 Test Agent - Use 'MD5' as SNMPv3 user and
> 'MD5UserAuthPassword' as authentication
> Type: OctetString
>
> OID: .1.3.6.1.2.1.1.2.0
> Value: .1.3.6.1.4.1.4976
> Type: OID
>
> OID: .1.3.6.1.2.1.1.3.0
> Value: 7 seconds (731)
> Type: TimeTicks
>
> OID: .1.3.6.1.2.1.1.4.0
> Value:
> Type: OctetString
>
> OID: .1.3.6.1.2.1.1.5.0
> Value:
> Type: OctetString
>
> OID: .1.3.6.1.2.1.1.6.0
> Value:
> Type: OctetString
>
> OID: .1.3.6.1.2.1.1.7.0
> Value: 10
> Type: Integer
>
> OID: .1.3.6.1.2.1.1.8.0
> Value: 0 millisecond (0)
> Type: TimeTicks
>
> OID: .1.3.6.1.2.1.11.1.0
> Value: 9
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.2.0
> Value: 9
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.3.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.4.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.5.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.6.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.8.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.9.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.10.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.11.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.12.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.13.0
> Value: 19
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.14.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.15.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.16.0
> Value: 22
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.17.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.18.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.19.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.20.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.21.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.22.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.24.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.25.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.26.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.27.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.28.0
> Value: 33
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.29.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.30.0
> Value: disabled (2)
> Type: Integer
>
> OID: .1.3.6.1.2.1.11.31.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.2.1.11.32.0
> Value: 0
> Type: Counter32
>
> OID: .1.3.6.1.4.1.4976.6.1.2.2.1.0
> Value: 1
> Type: Integer
>
> OID: .1.3.6.1.6.3.12.1.1.0
> Value: 0
> Type: Integer
> ==
>
> Why this project doesn't work for me?
> Thanks!
>
> Oleg
>
> _______________________________________________
> AGENTPP mailing list
> AGENTPP at agentpp.org
> https://oosnmp.net/mailman/listinfo/agentpp
--
---
AGENT++
Maximilian-Kolbe-Str. 10
73257 Koengen, Germany
https://agentpp.com
Phone: +49 7024 8688230
Fax: +49 7024 8688231
More information about the AGENTPP
mailing list