[SNMP4J] How to populate v2Trap PDU?
Deon van der Merwe
dvdm at truteq.co.za
Thu May 10 08:32:21 CEST 2007
Hi ,
At 11:54 PM 5/9/2007, sitakanta hotta wrote:
>Hi,
>
>Varbind list in v2Trap and inform pdus has the following
>pairs of object names and values:
>1.sysUpTime.0
>2. snmpTrapOid.0
>additional varbinds . . .
>
>How to set up first 2 parameters( i.e. sysUpTime.0 and snmpTrapOid.0) in
>PDU(*org.snmp4j.PDU* ) class ?
org.snmp4j.PDU vInformPdu = new org.snmp4j.PDU();
vInformPdu.setType(org.snmp4j.PDU.INFORM);
vInformPdu.add(new
org.snmp4j.smi.VariableBinding(org.snmp4j.mp.SnmpConstants.sysUpTime,
new org.snmp4j.smi.TimeTicks((java.lang.System.currentTimeMillis() -
mStartTime)/10)));
vInformPdu.add(new
org.snmp4j.smi.VariableBinding(org.snmp4j.mp.SnmpConstants.snmpTrapOID,
new org.snmp4j.smi.OID(aHolder.getOID())));
vInformPdu.add(new org.snmp4j.smi.VariableBinding(new
org.snmp4j.smi.OID(aHolder.getOID()), new
org.snmp4j.smi.OctetString(aHolder.getName())));
-Deon
_____________________________________________________
TruTeq Wireless (Pty) Ltd. | Tel: +27 (0)12 667 1530
http://www.truteq.co.za | Fax: +27 (0)12 667 1531
"Failure is more frequently from want of energy than want of capital."
More information about the SNMP4J
mailing list