[SNMP4J] MIBDesigner reports syntax...

Frank Fock fock at agentpp.com
Mon Oct 28 16:48:19 CET 2013


Hi Josef,

To fix the first error, you need to use a enumeration label that starts with
a lowercase letter (as far as I know <LOWERCASENAME> is also printed
out in the error message by MIB Designer).

The second might look like a bug but is most likely caused by a previous
error in the MIB which did not allow to parse the OBJECT-TYPE definition
as such.

Hope this helps.

Best regards,
Frank

Am 28.10.2013 09:20, schrieb Jozsef Lazar:
> Hi,
>
> I'm running MIBDesigner v3.2 which sends the following syntax errors:
>
> 1. construct in my MIB:
>
> o2StorageStatus OBJECT-TYPE
>         SYNTAX  INTEGER {
>                         OK(1),
>                         Error(2) }
>         MAX-ACCESS read-only
>         STATUS  current
>         DESCRIPTION
>                 "Accessibility information."
> -- 1.3.6.1.4.1.33687.1.1.1.2.1.8 --  ::= { o2StorageTableEntry 8 }
>
> for which the designer sends the following syntax error.
>
> #1: [1000] Syntax error: Encountered "OK" at line 284, column 25:
> Was expecting one of:
>   "obsolete" ...
>   "optional" ...
>   "deprecated" ...
>   "mandatory" ...
>   "current" ...
>    ...
>
> 2. construct in the MIB:
>
> o2VPUptime OBJECT-TYPE
>         SYNTAX  Unsigned32
>         MAX-ACCESS read-only
>         STATUS  current
>         DESCRIPTION
>                 "The time (in UNIX seconds) since the NETAVIS
>                 video platform has been started."
> -- 1.3.6.1.4.1.33687.1.1.2.8 --  ::= { o2VideoPlatform 8 }
>
> then a reference to it in the group:
>
> o2BasicGroup OBJECT-GROUP
>         OBJECTS {
>                 ...
>                 o2VPUptime,
>                 ... }
>         STATUS  current
>         DESCRIPTION
>                 "Basic objects."
> -- 1.3.6.1.4.1.33687.1.3.1.1 --  ::= { o2Groups 1 }
>
> message from designer:
>
> #8: [1700] Object reference with wrong type: o2VPUptime at line 949, 
> column 17,
> expected type was OBJECT-TYPE, but found OBJECT IDENTIFIER instead
>
> Please help me, what am I doing (understanding) wrong?
>
>
> Josef
>
> _______________________________________________
> SNMP4J mailing list
> SNMP4J at agentpp.org
> http://lists.agentpp.org/mailman/listinfo/snmp4j

-- 
---