<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE smi SYSTEM "http://www.mibexplorer.com/DTD/SMI.DTD">

<smi>
        <module name="BRIDGE-MIB" language="SMIv1"/>
        <imports>
                <import module="RFC1155-SMI" name="Counter"/>
                <import module="RFC1155-SMI" name="TimeTicks"/>
                <import module="RFC1213-MIB" name="mib-2"/>
                <import module="RFC-1212" name="OBJECT-TYPE"/>
                <import module="RFC-1215" name="TRAP-TYPE"/>
        </imports>
        <typedefs>
                <typedef parent="BRIDGE-MIB" name="Timeout" basetype="INTEGER" status="undefined"/>
                <typedef parent="BRIDGE-MIB" name="MacAddress" basetype="OCTET STRING" status="undefined">
                        <range min="6" max="6"/>
                </typedef>
                <typedef parent="BRIDGE-MIB" name="BridgeId" basetype="OCTET STRING" status="undefined">
                        <range min="8" max="8"/>
                </typedef>
        </typedefs>
        <nodes>
                <node name="dot1dBridge" oid="1.3.6.1.2.1.17"/>
                <node name="dot1dBase" oid="1.3.6.1.2.1.17.1"/>
                <scalar name="dot1dBaseBridgeAddress" oid="1.3.6.1.2.1.17.1.1" status="mandatory">
                        <syntax>
                                <type name="MacAddress" module="BRIDGE-MIB"/>
                        </syntax>
                        <access>readonly</access>
                        <description><![CDATA[The MAC address used by this bridge when it must
be referred to in a unique fashion.   It is
recommended that this be the numerically smallest
MAC address of all ports that belong to this
bridge.  However it is only required to be unique.
When concatenated with dot1dStpPriority a unique
BridgeIdentifier is formed which is used in the
Spanning Tree Protocol.]]></description>
                        <reference><![CDATA[IEEE 802.1D-1990: Sections 6.4.1.1.3 and 3.12.5]]></reference>
                </scalar>
                <scalar name="dot1dBaseNumPorts" oid="1.3.6.1.2.1.17.1.2" status="mandatory">
                        <syntax>
                                <type name="INTEGER" module=""/>
                        </syntax>
                        <access>readonly</access>
                        <description><![CDATA[The number of ports controlled by this bridging
entity.]]></description>
                        <reference><![CDATA[IEEE 802.1D-1990: Section 6.4.1.1.3]]></reference>
                </scalar>
                <scalar name="dot1dBaseType" oid="1.3.6.1.2.1.17.1.3" status="mandatory">
                        <syntax>
                                <typedef basetype="INTEGER">
                                        <namednumber name="unknown" number="1"/>
                                        <namednumber name="transparent-only" number="2"/>
                                        <namednumber name="sourceroute-only" number="3"/>
                                        <namednumber name="srt" number="4"/>
                                </typedef>
                        </syntax>
                        <access>readonly</access>
                        <description><![CDATA[Indicates what type of bridging this bridge can
perform.  If a bridge is actually performing a
certain type of bridging this will be indicated by
entries in the port table for the given type.]]></description>
                </scalar>
                <table name="dot1dBasePortTable" oid="1.3.6.1.2.1.17.1.4" status="mandatory">
                        <description><![CDATA[A table that contains generic information about
every port that is associated with this bridge.
Transparent, source-route, and srt ports are
included.]]></description>
                        <row name="dot1dBasePortEntry" oid="1.3.6.1.2.1.17.1.4.1" status="mandatory" create="false">
                                <linkage implied="false">
                                        <index module="BRIDGE-MIB" name="dot1dBasePort"/>
                                </linkage>
                                <description><![CDATA[A list of information for each port of the
bridge.]]></description>
                                <reference><![CDATA[IEEE 802.1D-1990: Section 6.4.2, 6.6.1]]></reference>
                                <column name="dot1dBasePort" oid="1.3.6.1.2.1.17.1.4.1.1" status="mandatory">
                                        <syntax>
                                                <typedef basetype="INTEGER">
                                                        <range min="1" max="65535"/>
                                                </typedef>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The port number of the port for which this entry
contains bridge management information.]]></description>
                                </column>
                                <column name="dot1dBasePortIfIndex" oid="1.3.6.1.2.1.17.1.4.1.2" status="mandatory">
                                        <syntax>
                                                <type name="INTEGER" module=""/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The value of the instance of the ifIndex object,
defined in MIB-II, for the interface corresponding
to this port.]]></description>
                                </column>
                                <column name="dot1dBasePortCircuit" oid="1.3.6.1.2.1.17.1.4.1.3" status="mandatory">
                                        <syntax>
                                                <type name="OBJECT IDENTIFIER" module=""/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[For a port which (potentially) has the same value
of dot1dBasePortIfIndex as another port on the
same bridge, this object contains the name of an
object instance unique to this port.  For example,
in the case where multiple ports correspond one-
to-one with multiple X.25 virtual circuits, this
value might identify an (e.g., the first) object
instance associated with the X.25 virtual circuit
corresponding to this port.

For a port which has a unique value of
dot1dBasePortIfIndex, this object can have the
value { 0 0 }.]]></description>
                                </column>
                                <column name="dot1dBasePortDelayExceededDiscards" oid="1.3.6.1.2.1.17.1.4.1.4" status="mandatory">
                                        <syntax>
                                                <type name="Counter" module=""/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The number of frames discarded by this port due
to excessive transit delay through the bridge.  It
is incremented by both transparent and source
route bridges.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 6.6.1.1.3]]></reference>
                                </column>
                                <column name="dot1dBasePortMtuExceededDiscards" oid="1.3.6.1.2.1.17.1.4.1.5" status="mandatory">
                                        <syntax>
                                                <type name="Counter" module=""/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The number of frames discarded by this port due
to an excessive size.  It is incremented by both
transparent and source route bridges.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 6.6.1.1.3]]></reference>
                                </column>
                        </row>
                </table>
                <table name="dot1dBasePortEntry" oid="1.3.6.1.2.1.17.1.4.1" status="mandatory">
                        <description><![CDATA[A list of information for each port of the
bridge.]]></description>
                        <reference><![CDATA[IEEE 802.1D-1990: Section 6.4.2, 6.6.1]]></reference>
                        <row name="dot1dBasePortEntry" oid="1.3.6.1.2.1.17.1.4.1" status="mandatory" create="false">
                                <linkage implied="false">
                                        <index module="BRIDGE-MIB" name="dot1dBasePort"/>
                                </linkage>
                                <description><![CDATA[A list of information for each port of the
bridge.]]></description>
                                <reference><![CDATA[IEEE 802.1D-1990: Section 6.4.2, 6.6.1]]></reference>
                                <column name="dot1dBasePort" oid="1.3.6.1.2.1.17.1.4.1.1" status="mandatory">
                                        <syntax>
                                                <typedef basetype="INTEGER">
                                                        <range min="1" max="65535"/>
                                                </typedef>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The port number of the port for which this entry
contains bridge management information.]]></description>
                                </column>
                                <column name="dot1dBasePortIfIndex" oid="1.3.6.1.2.1.17.1.4.1.2" status="mandatory">
                                        <syntax>
                                                <type name="INTEGER" module=""/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The value of the instance of the ifIndex object,
defined in MIB-II, for the interface corresponding
to this port.]]></description>
                                </column>
                                <column name="dot1dBasePortCircuit" oid="1.3.6.1.2.1.17.1.4.1.3" status="mandatory">
                                        <syntax>
                                                <type name="OBJECT IDENTIFIER" module=""/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[For a port which (potentially) has the same value
of dot1dBasePortIfIndex as another port on the
same bridge, this object contains the name of an
object instance unique to this port.  For example,
in the case where multiple ports correspond one-
to-one with multiple X.25 virtual circuits, this
value might identify an (e.g., the first) object
instance associated with the X.25 virtual circuit
corresponding to this port.

For a port which has a unique value of
dot1dBasePortIfIndex, this object can have the
value { 0 0 }.]]></description>
                                </column>
                                <column name="dot1dBasePortDelayExceededDiscards" oid="1.3.6.1.2.1.17.1.4.1.4" status="mandatory">
                                        <syntax>
                                                <type name="Counter" module=""/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The number of frames discarded by this port due
to excessive transit delay through the bridge.  It
is incremented by both transparent and source
route bridges.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 6.6.1.1.3]]></reference>
                                </column>
                                <column name="dot1dBasePortMtuExceededDiscards" oid="1.3.6.1.2.1.17.1.4.1.5" status="mandatory">
                                        <syntax>
                                                <type name="Counter" module=""/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The number of frames discarded by this port due
to an excessive size.  It is incremented by both
transparent and source route bridges.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 6.6.1.1.3]]></reference>
                                </column>
                        </row>
                </table>
                <node name="dot1dStp" oid="1.3.6.1.2.1.17.2"/>
                <scalar name="dot1dStpProtocolSpecification" oid="1.3.6.1.2.1.17.2.1" status="mandatory">
                        <syntax>
                                <typedef basetype="INTEGER">
                                        <namednumber name="unknown" number="1"/>
                                        <namednumber name="decLb100" number="2"/>
                                        <namednumber name="ieee8021d" number="3"/>
                                </typedef>
                        </syntax>
                        <access>readonly</access>
                        <description><![CDATA[An indication of what version of the Spanning
Tree Protocol is being run.  The value
'decLb100(2)' indicates the DEC LANbridge 100
Spanning Tree protocol.  IEEE 802.1d
implementations will return 'ieee8021d(3)'.  If
future versions of the IEEE Spanning Tree Protocol
are released that are incompatible with the
current version a new value will be defined.]]></description>
                </scalar>
                <scalar name="dot1dStpPriority" oid="1.3.6.1.2.1.17.2.2" status="mandatory">
                        <syntax>
                                <typedef basetype="INTEGER">
                                        <range min="0" max="65535"/>
                                </typedef>
                        </syntax>
                        <access>readwrite</access>
                        <description><![CDATA[The value of the write-able portion of the Bridge
ID, i.e., the first two octets of the (8 octet
long) Bridge ID.  The other (last) 6 octets of the
Bridge ID are given by the value of
dot1dBaseBridgeAddress.]]></description>
                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.3.7]]></reference>
                </scalar>
                <scalar name="dot1dStpTimeSinceTopologyChange" oid="1.3.6.1.2.1.17.2.3" status="mandatory">
                        <syntax>
                                <type name="TimeTicks" module=""/>
                        </syntax>
                        <access>readonly</access>
                        <description><![CDATA[The time (in hundredths of a second) since the
last time a topology change was detected by the
bridge entity.]]></description>
                        <reference><![CDATA[IEEE 802.1D-1990: Section 6.8.1.1.3]]></reference>
                </scalar>
                <scalar name="dot1dStpTopChanges" oid="1.3.6.1.2.1.17.2.4" status="mandatory">
                        <syntax>
                                <type name="Counter" module=""/>
                        </syntax>
                        <access>readonly</access>
                        <description><![CDATA[The total number of topology changes detected by
this bridge since the management entity was last
reset or initialized.]]></description>
                        <reference><![CDATA[IEEE 802.1D-1990: Section 6.8.1.1.3]]></reference>
                </scalar>
                <scalar name="dot1dStpDesignatedRoot" oid="1.3.6.1.2.1.17.2.5" status="mandatory">
                        <syntax>
                                <type name="BridgeId" module="BRIDGE-MIB"/>
                        </syntax>
                        <access>readonly</access>
                        <description><![CDATA[The bridge identifier of the root of the spanning
tree as determined by the Spanning Tree Protocol
as executed by this node.  This value is used as
the Root Identifier parameter in all Configuration
Bridge PDUs originated by this node.]]></description>
                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.3.1]]></reference>
                </scalar>
                <scalar name="dot1dStpRootCost" oid="1.3.6.1.2.1.17.2.6" status="mandatory">
                        <syntax>
                                <type name="INTEGER" module=""/>
                        </syntax>
                        <access>readonly</access>
                        <description><![CDATA[The cost of the path to the root as seen from
this bridge.]]></description>
                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.3.2]]></reference>
                </scalar>
                <scalar name="dot1dStpRootPort" oid="1.3.6.1.2.1.17.2.7" status="mandatory">
                        <syntax>
                                <type name="INTEGER" module=""/>
                        </syntax>
                        <access>readonly</access>
                        <description><![CDATA[The port number of the port which offers the
lowest cost path from this bridge to the root
bridge.]]></description>
                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.3.3]]></reference>
                </scalar>
                <scalar name="dot1dStpMaxAge" oid="1.3.6.1.2.1.17.2.8" status="mandatory">
                        <syntax>
                                <type name="Timeout" module="BRIDGE-MIB"/>
                        </syntax>
                        <access>readonly</access>
                        <description><![CDATA[The maximum age of Spanning Tree Protocol
information learned from the network on any port
before it is discarded, in units of hundredths of
a second.  This is the actual value that this
bridge is currently using.]]></description>
                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.3.4]]></reference>
                </scalar>
                <scalar name="dot1dStpHelloTime" oid="1.3.6.1.2.1.17.2.9" status="mandatory">
                        <syntax>
                                <type name="Timeout" module="BRIDGE-MIB"/>
                        </syntax>
                        <access>readonly</access>
                        <description><![CDATA[The amount of time between the transmission of
Configuration bridge PDUs by this node on any port
when it is the root of the spanning tree or trying
to become so, in units of hundredths of a second.
This is the actual value that this bridge is
currently using.]]></description>
                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.3.5]]></reference>
                </scalar>
                <scalar name="dot1dStpHoldTime" oid="1.3.6.1.2.1.17.2.10" status="mandatory">
                        <syntax>
                                <type name="INTEGER" module=""/>
                        </syntax>
                        <access>readonly</access>
                        <description><![CDATA[This time value determines the interval length
during which no more than two Configuration bridge
PDUs shall be transmitted by this node, in units
of hundredths of a second.]]></description>
                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.3.14]]></reference>
                </scalar>
                <scalar name="dot1dStpForwardDelay" oid="1.3.6.1.2.1.17.2.11" status="mandatory">
                        <syntax>
                                <type name="Timeout" module="BRIDGE-MIB"/>
                        </syntax>
                        <access>readonly</access>
                        <description><![CDATA[This time value, measured in units of hundredths
of a second, controls how fast a port changes its
spanning state when moving towards the Forwarding
state.  The value determines how long the port
stays in each of the Listening and Learning
states, which precede the Forwarding state.  This
value is also used, when a topology change has
been detected and is underway, to age all dynamic
entries in the Forwarding Database.  [Note that
this value is the one that this bridge is
currently using, in contrast to
dot1dStpBridgeForwardDelay which is the value that
this bridge and all others would start using
if/when this bridge were to become the root.]]]></description>
                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.3.6]]></reference>
                </scalar>
                <scalar name="dot1dStpBridgeMaxAge" oid="1.3.6.1.2.1.17.2.12" status="mandatory">
                        <syntax>
                                <typedef basetype="Timeout">
                                        <range min="600" max="4000"/>
                                </typedef>
                        </syntax>
                        <access>readwrite</access>
                        <description><![CDATA[The value that all bridges use for MaxAge when
this bridge is acting as the root.  Note that
802.1D-1990 specifies that the range for this
parameter is related to the value of
dot1dStpBridgeHelloTime. The granularity of this
timer is specified by 802.1D-1990 to be 1 second.
An agent may return a badValue error if a set is
attempted to a value which is not a whole number
of seconds.]]></description>
                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.3.8]]></reference>
                </scalar>
                <scalar name="dot1dStpBridgeHelloTime" oid="1.3.6.1.2.1.17.2.13" status="mandatory">
                        <syntax>
                                <typedef basetype="Timeout">
                                        <range min="100" max="1000"/>
                                </typedef>
                        </syntax>
                        <access>readwrite</access>
                        <description><![CDATA[The value that all bridges use for HelloTime when
this bridge is acting as the root.  The
granularity of this timer is specified by 802.1D-
1990 to be 1 second.  An agent may return a
badValue error if a set is attempted to a value
which is not a whole number of seconds.]]></description>
                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.3.9]]></reference>
                </scalar>
                <scalar name="dot1dStpBridgeForwardDelay" oid="1.3.6.1.2.1.17.2.14" status="mandatory">
                        <syntax>
                                <typedef basetype="Timeout">
                                        <range min="400" max="3000"/>
                                </typedef>
                        </syntax>
                        <access>readwrite</access>
                        <description><![CDATA[The value that all bridges use for ForwardDelay
when this bridge is acting as the root.  Note that
802.1D-1990 specifies that the range for this
parameter is related to the value of
dot1dStpBridgeMaxAge.  The granularity of this
timer is specified by 802.1D-1990 to be 1 second.
An agent may return a badValue error if a set is
attempted to a value which is not a whole number
of seconds.]]></description>
                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.3.10]]></reference>
                </scalar>
                <table name="dot1dStpPortTable" oid="1.3.6.1.2.1.17.2.15" status="mandatory">
                        <description><![CDATA[A table that contains port-specific information
for the Spanning Tree Protocol.]]></description>
                        <row name="dot1dStpPortEntry" oid="1.3.6.1.2.1.17.2.15.1" status="mandatory" create="false">
                                <linkage implied="false">
                                        <index module="BRIDGE-MIB" name="dot1dStpPort"/>
                                </linkage>
                                <description><![CDATA[A list of information maintained by every port
about the Spanning Tree Protocol state for that
port.]]></description>
                                <column name="dot1dStpPort" oid="1.3.6.1.2.1.17.2.15.1.1" status="mandatory">
                                        <syntax>
                                                <typedef basetype="INTEGER">
                                                        <range min="1" max="65535"/>
                                                </typedef>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The port number of the port for which this entry
contains Spanning Tree Protocol management
information.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 6.8.2.1.2]]></reference>
                                </column>
                                <column name="dot1dStpPortPriority" oid="1.3.6.1.2.1.17.2.15.1.2" status="mandatory">
                                        <syntax>
                                                <typedef basetype="INTEGER">
                                                        <range min="0" max="255"/>
                                                </typedef>
                                        </syntax>
                                        <access>readwrite</access>
                                        <description><![CDATA[The value of the priority field which is
contained in the first (in network byte order)
octet of the (2 octet long) Port ID.  The other
octet of the Port ID is given by the value of
dot1dStpPort.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.5.1]]></reference>
                                </column>
                                <column name="dot1dStpPortState" oid="1.3.6.1.2.1.17.2.15.1.3" status="mandatory">
                                        <syntax>
                                                <typedef basetype="INTEGER">
                                                        <namednumber name="disabled" number="1"/>
                                                        <namednumber name="blocking" number="2"/>
                                                        <namednumber name="listening" number="3"/>
                                                        <namednumber name="learning" number="4"/>
                                                        <namednumber name="forwarding" number="5"/>
                                                        <namednumber name="broken" number="6"/>
                                                </typedef>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The port's current state as defined by
application of the Spanning Tree Protocol.  This
state controls what action a port takes on
reception of a frame.  If the bridge has detected
a port that is malfunctioning it will place that
port into the broken(6) state.  For ports which
are disabled (see dot1dStpPortEnable), this object
will have a value of disabled(1).]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.5.2]]></reference>
                                </column>
                                <column name="dot1dStpPortEnable" oid="1.3.6.1.2.1.17.2.15.1.4" status="mandatory">
                                        <syntax>
                                                <typedef basetype="INTEGER">
                                                        <namednumber name="enabled" number="1"/>
                                                        <namednumber name="disabled" number="2"/>
                                                </typedef>
                                        </syntax>
                                        <access>readwrite</access>
                                        <description><![CDATA[The enabled/disabled status of the port.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.5.2]]></reference>
                                </column>
                                <column name="dot1dStpPortPathCost" oid="1.3.6.1.2.1.17.2.15.1.5" status="mandatory">
                                        <syntax>
                                                <typedef basetype="INTEGER">
                                                        <range min="1" max="65535"/>
                                                </typedef>
                                        </syntax>
                                        <access>readwrite</access>
                                        <description><![CDATA[The contribution of this port to the path cost of
paths towards the spanning tree root which include
this port.  802.1D-1990 recommends that the
default value of this parameter be in inverse
proportion to the speed of the attached LAN.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.5.3]]></reference>
                                </column>
                                <column name="dot1dStpPortDesignatedRoot" oid="1.3.6.1.2.1.17.2.15.1.6" status="mandatory">
                                        <syntax>
                                                <type name="BridgeId" module="BRIDGE-MIB"/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The unique Bridge Identifier of the Bridge
recorded as the Root in the Configuration BPDUs
transmitted by the Designated Bridge for the
segment to which the port is attached.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.5.4]]></reference>
                                </column>
                                <column name="dot1dStpPortDesignatedCost" oid="1.3.6.1.2.1.17.2.15.1.7" status="mandatory">
                                        <syntax>
                                                <type name="INTEGER" module=""/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The path cost of the Designated Port of the
segment connected to this port.  This value is
compared to the Root Path Cost field in received
bridge PDUs.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.5.5]]></reference>
                                </column>
                                <column name="dot1dStpPortDesignatedBridge" oid="1.3.6.1.2.1.17.2.15.1.8" status="mandatory">
                                        <syntax>
                                                <type name="BridgeId" module="BRIDGE-MIB"/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The Bridge Identifier of the bridge which this
port considers to be the Designated Bridge for
this port's segment.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.5.6]]></reference>
                                </column>
                                <column name="dot1dStpPortDesignatedPort" oid="1.3.6.1.2.1.17.2.15.1.9" status="mandatory">
                                        <syntax>
                                                <typedef basetype="OCTET STRING">
                                                        <range min="2" max="2"/>
                                                </typedef>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The Port Identifier of the port on the Designated
Bridge for this port's segment.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.5.7]]></reference>
                                </column>
                                <column name="dot1dStpPortForwardTransitions" oid="1.3.6.1.2.1.17.2.15.1.10" status="mandatory">
                                        <syntax>
                                                <type name="Counter" module=""/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The number of times this port has transitioned
from the Learning state to the Forwarding state.]]></description>
                                </column>
                        </row>
                </table>
                <table name="dot1dStpPortEntry" oid="1.3.6.1.2.1.17.2.15.1" status="mandatory">
                        <description><![CDATA[A list of information maintained by every port
about the Spanning Tree Protocol state for that
port.]]></description>
                        <row name="dot1dStpPortEntry" oid="1.3.6.1.2.1.17.2.15.1" status="mandatory" create="false">
                                <linkage implied="false">
                                        <index module="BRIDGE-MIB" name="dot1dStpPort"/>
                                </linkage>
                                <description><![CDATA[A list of information maintained by every port
about the Spanning Tree Protocol state for that
port.]]></description>
                                <column name="dot1dStpPort" oid="1.3.6.1.2.1.17.2.15.1.1" status="mandatory">
                                        <syntax>
                                                <typedef basetype="INTEGER">
                                                        <range min="1" max="65535"/>
                                                </typedef>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The port number of the port for which this entry
contains Spanning Tree Protocol management
information.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 6.8.2.1.2]]></reference>
                                </column>
                                <column name="dot1dStpPortPriority" oid="1.3.6.1.2.1.17.2.15.1.2" status="mandatory">
                                        <syntax>
                                                <typedef basetype="INTEGER">
                                                        <range min="0" max="255"/>
                                                </typedef>
                                        </syntax>
                                        <access>readwrite</access>
                                        <description><![CDATA[The value of the priority field which is
contained in the first (in network byte order)
octet of the (2 octet long) Port ID.  The other
octet of the Port ID is given by the value of
dot1dStpPort.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.5.1]]></reference>
                                </column>
                                <column name="dot1dStpPortState" oid="1.3.6.1.2.1.17.2.15.1.3" status="mandatory">
                                        <syntax>
                                                <typedef basetype="INTEGER">
                                                        <namednumber name="disabled" number="1"/>
                                                        <namednumber name="blocking" number="2"/>
                                                        <namednumber name="listening" number="3"/>
                                                        <namednumber name="learning" number="4"/>
                                                        <namednumber name="forwarding" number="5"/>
                                                        <namednumber name="broken" number="6"/>
                                                </typedef>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The port's current state as defined by
application of the Spanning Tree Protocol.  This
state controls what action a port takes on
reception of a frame.  If the bridge has detected
a port that is malfunctioning it will place that
port into the broken(6) state.  For ports which
are disabled (see dot1dStpPortEnable), this object
will have a value of disabled(1).]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.5.2]]></reference>
                                </column>
                                <column name="dot1dStpPortEnable" oid="1.3.6.1.2.1.17.2.15.1.4" status="mandatory">
                                        <syntax>
                                                <typedef basetype="INTEGER">
                                                        <namednumber name="enabled" number="1"/>
                                                        <namednumber name="disabled" number="2"/>
                                                </typedef>
                                        </syntax>
                                        <access>readwrite</access>
                                        <description><![CDATA[The enabled/disabled status of the port.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.5.2]]></reference>
                                </column>
                                <column name="dot1dStpPortPathCost" oid="1.3.6.1.2.1.17.2.15.1.5" status="mandatory">
                                        <syntax>
                                                <typedef basetype="INTEGER">
                                                        <range min="1" max="65535"/>
                                                </typedef>
                                        </syntax>
                                        <access>readwrite</access>
                                        <description><![CDATA[The contribution of this port to the path cost of
paths towards the spanning tree root which include
this port.  802.1D-1990 recommends that the
default value of this parameter be in inverse
proportion to the speed of the attached LAN.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.5.3]]></reference>
                                </column>
                                <column name="dot1dStpPortDesignatedRoot" oid="1.3.6.1.2.1.17.2.15.1.6" status="mandatory">
                                        <syntax>
                                                <type name="BridgeId" module="BRIDGE-MIB"/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The unique Bridge Identifier of the Bridge
recorded as the Root in the Configuration BPDUs
transmitted by the Designated Bridge for the
segment to which the port is attached.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.5.4]]></reference>
                                </column>
                                <column name="dot1dStpPortDesignatedCost" oid="1.3.6.1.2.1.17.2.15.1.7" status="mandatory">
                                        <syntax>
                                                <type name="INTEGER" module=""/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The path cost of the Designated Port of the
segment connected to this port.  This value is
compared to the Root Path Cost field in received
bridge PDUs.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.5.5]]></reference>
                                </column>
                                <column name="dot1dStpPortDesignatedBridge" oid="1.3.6.1.2.1.17.2.15.1.8" status="mandatory">
                                        <syntax>
                                                <type name="BridgeId" module="BRIDGE-MIB"/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The Bridge Identifier of the bridge which this
port considers to be the Designated Bridge for
this port's segment.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.5.6]]></reference>
                                </column>
                                <column name="dot1dStpPortDesignatedPort" oid="1.3.6.1.2.1.17.2.15.1.9" status="mandatory">
                                        <syntax>
                                                <typedef basetype="OCTET STRING">
                                                        <range min="2" max="2"/>
                                                </typedef>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The Port Identifier of the port on the Designated
Bridge for this port's segment.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 4.5.5.7]]></reference>
                                </column>
                                <column name="dot1dStpPortForwardTransitions" oid="1.3.6.1.2.1.17.2.15.1.10" status="mandatory">
                                        <syntax>
                                                <type name="Counter" module=""/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The number of times this port has transitioned
from the Learning state to the Forwarding state.]]></description>
                                </column>
                        </row>
                </table>
                <node name="dot1dSr" oid="1.3.6.1.2.1.17.3"/>
                <node name="dot1dTp" oid="1.3.6.1.2.1.17.4"/>
                <scalar name="dot1dTpLearnedEntryDiscards" oid="1.3.6.1.2.1.17.4.1" status="mandatory">
                        <syntax>
                                <type name="Counter" module=""/>
                        </syntax>
                        <access>readonly</access>
                        <description><![CDATA[The total number of Forwarding Database entries,
which have been or would have been learnt, but
have been discarded due to a lack of space to
store them in the Forwarding Database.  If this
counter is increasing, it indicates that the
Forwarding Database is regularly becoming full (a
condition which has unpleasant performance effects
on the subnetwork).  If this counter has a
significant value but is not presently increasing,
it indicates that the problem has been occurring
but is not persistent.]]></description>
                        <reference><![CDATA[IEEE 802.1D-1990: Section 6.7.1.1.3]]></reference>
                </scalar>
                <scalar name="dot1dTpAgingTime" oid="1.3.6.1.2.1.17.4.2" status="mandatory">
                        <syntax>
                                <typedef basetype="INTEGER">
                                        <range min="10" max="1000000"/>
                                </typedef>
                        </syntax>
                        <access>readwrite</access>
                        <description><![CDATA[The timeout period in seconds for aging out
dynamically learned forwarding information.
802.1D-1990 recommends a default of 300 seconds.]]></description>
                        <reference><![CDATA[IEEE 802.1D-1990: Section 6.7.1.1.3]]></reference>
                </scalar>
                <table name="dot1dTpFdbTable" oid="1.3.6.1.2.1.17.4.3" status="mandatory">
                        <description><![CDATA[A table that contains information about unicast
entries for which the bridge has forwarding and/or
filtering information.  This information is used
by the transparent bridging function in
determining how to propagate a received frame.]]></description>
                        <row name="dot1dTpFdbEntry" oid="1.3.6.1.2.1.17.4.3.1" status="mandatory" create="false">
                                <linkage implied="false">
                                        <index module="BRIDGE-MIB" name="dot1dTpFdbAddress"/>
                                </linkage>
                                <description><![CDATA[Information about a specific unicast MAC address
for which the bridge has some forwarding and/or
filtering information.]]></description>
                                <column name="dot1dTpFdbAddress" oid="1.3.6.1.2.1.17.4.3.1.1" status="mandatory">
                                        <syntax>
                                                <type name="MacAddress" module="BRIDGE-MIB"/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[A unicast MAC address for which the bridge has
forwarding and/or filtering information.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 3.9.1, 3.9.2]]></reference>
                                </column>
                                <column name="dot1dTpFdbPort" oid="1.3.6.1.2.1.17.4.3.1.2" status="mandatory">
                                        <syntax>
                                                <type name="INTEGER" module=""/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[Either the value '0', or the port number of the
port on which a frame having a source address
equal to the value of the corresponding instance
of dot1dTpFdbAddress has been seen.  A value of
'0' indicates that the port number has not been
learned but that the bridge does have some
forwarding/filtering information about this
address (e.g. in the dot1dStaticTable).
Implementors are encouraged to assign the port
value to this object whenever it is learned even
for addresses for which the corresponding value of
dot1dTpFdbStatus is not learned(3).]]></description>
                                </column>
                                <column name="dot1dTpFdbStatus" oid="1.3.6.1.2.1.17.4.3.1.3" status="mandatory">
                                        <syntax>
                                                <typedef basetype="INTEGER">
                                                        <namednumber name="other" number="1"/>
                                                        <namednumber name="invalid" number="2"/>
                                                        <namednumber name="learned" number="3"/>
                                                        <namednumber name="self" number="4"/>
                                                        <namednumber name="mgmt" number="5"/>
                                                </typedef>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The status of this entry.  The meanings of the
values are:

  other(1)   : none of the following.  This would
               include the case where some other
               MIB object (not the corresponding
               instance of dot1dTpFdbPort, nor an
               entry in the dot1dStaticTable) is
               being used to determine if and how
               frames addressed to the value of
               the corresponding instance of
               dot1dTpFdbAddress are being
               forwarded.

  invalid(2) : this entry is not longer valid
               (e.g., it was learned but has since
               aged-out), but has not yet been
               flushed from the table.

  learned(3) : the value of the corresponding
               instance of dot1dTpFdbPort was
               learned, and is being used.

  self(4)    : the value of the corresponding
               instance of dot1dTpFdbAddress
               represents one of the bridge's
               addresses.  The corresponding
               instance of dot1dTpFdbPort
               indicates which of the bridge's
               ports has this address.

  mgmt(5)    : the value of the corresponding
               instance of dot1dTpFdbAddress is
               also the value of an existing
               instance of dot1dStaticAddress.]]></description>
                                </column>
                        </row>
                </table>
                <table name="dot1dTpFdbEntry" oid="1.3.6.1.2.1.17.4.3.1" status="mandatory">
                        <description><![CDATA[Information about a specific unicast MAC address
for which the bridge has some forwarding and/or
filtering information.]]></description>
                        <row name="dot1dTpFdbEntry" oid="1.3.6.1.2.1.17.4.3.1" status="mandatory" create="false">
                                <linkage implied="false">
                                        <index module="BRIDGE-MIB" name="dot1dTpFdbAddress"/>
                                </linkage>
                                <description><![CDATA[Information about a specific unicast MAC address
for which the bridge has some forwarding and/or
filtering information.]]></description>
                                <column name="dot1dTpFdbAddress" oid="1.3.6.1.2.1.17.4.3.1.1" status="mandatory">
                                        <syntax>
                                                <type name="MacAddress" module="BRIDGE-MIB"/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[A unicast MAC address for which the bridge has
forwarding and/or filtering information.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 3.9.1, 3.9.2]]></reference>
                                </column>
                                <column name="dot1dTpFdbPort" oid="1.3.6.1.2.1.17.4.3.1.2" status="mandatory">
                                        <syntax>
                                                <type name="INTEGER" module=""/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[Either the value '0', or the port number of the
port on which a frame having a source address
equal to the value of the corresponding instance
of dot1dTpFdbAddress has been seen.  A value of
'0' indicates that the port number has not been
learned but that the bridge does have some
forwarding/filtering information about this
address (e.g. in the dot1dStaticTable).
Implementors are encouraged to assign the port
value to this object whenever it is learned even
for addresses for which the corresponding value of
dot1dTpFdbStatus is not learned(3).]]></description>
                                </column>
                                <column name="dot1dTpFdbStatus" oid="1.3.6.1.2.1.17.4.3.1.3" status="mandatory">
                                        <syntax>
                                                <typedef basetype="INTEGER">
                                                        <namednumber name="other" number="1"/>
                                                        <namednumber name="invalid" number="2"/>
                                                        <namednumber name="learned" number="3"/>
                                                        <namednumber name="self" number="4"/>
                                                        <namednumber name="mgmt" number="5"/>
                                                </typedef>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The status of this entry.  The meanings of the
values are:

  other(1)   : none of the following.  This would
               include the case where some other
               MIB object (not the corresponding
               instance of dot1dTpFdbPort, nor an
               entry in the dot1dStaticTable) is
               being used to determine if and how
               frames addressed to the value of
               the corresponding instance of
               dot1dTpFdbAddress are being
               forwarded.

  invalid(2) : this entry is not longer valid
               (e.g., it was learned but has since
               aged-out), but has not yet been
               flushed from the table.

  learned(3) : the value of the corresponding
               instance of dot1dTpFdbPort was
               learned, and is being used.

  self(4)    : the value of the corresponding
               instance of dot1dTpFdbAddress
               represents one of the bridge's
               addresses.  The corresponding
               instance of dot1dTpFdbPort
               indicates which of the bridge's
               ports has this address.

  mgmt(5)    : the value of the corresponding
               instance of dot1dTpFdbAddress is
               also the value of an existing
               instance of dot1dStaticAddress.]]></description>
                                </column>
                        </row>
                </table>
                <table name="dot1dTpPortTable" oid="1.3.6.1.2.1.17.4.4" status="mandatory">
                        <description><![CDATA[A table that contains information about every
port that is associated with this transparent
bridge.]]></description>
                        <row name="dot1dTpPortEntry" oid="1.3.6.1.2.1.17.4.4.1" status="mandatory" create="false">
                                <linkage implied="false">
                                        <index module="BRIDGE-MIB" name="dot1dTpPort"/>
                                </linkage>
                                <description><![CDATA[A list of information for each port of a
transparent bridge.]]></description>
                                <column name="dot1dTpPort" oid="1.3.6.1.2.1.17.4.4.1.1" status="mandatory">
                                        <syntax>
                                                <typedef basetype="INTEGER">
                                                        <range min="1" max="65535"/>
                                                </typedef>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The port number of the port for which this entry
contains Transparent bridging management
information.]]></description>
                                </column>
                                <column name="dot1dTpPortMaxInfo" oid="1.3.6.1.2.1.17.4.4.1.2" status="mandatory">
                                        <syntax>
                                                <type name="INTEGER" module=""/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The maximum size of the INFO (non-MAC) field that
this port will receive or transmit.]]></description>
                                </column>
                                <column name="dot1dTpPortInFrames" oid="1.3.6.1.2.1.17.4.4.1.3" status="mandatory">
                                        <syntax>
                                                <type name="Counter" module=""/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The number of frames that have been received by
this port from its segment. Note that a frame
received on the interface corresponding to this
port is only counted by this object if and only if
it is for a protocol being processed by the local
bridging function, including bridge management
frames.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 6.6.1.1.3]]></reference>
                                </column>
                                <column name="dot1dTpPortOutFrames" oid="1.3.6.1.2.1.17.4.4.1.4" status="mandatory">
                                        <syntax>
                                                <type name="Counter" module=""/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The number of frames that have been transmitted
by this port to its segment.  Note that a frame
transmitted on the interface corresponding to this
port is only counted by this object if and only if
it is for a protocol being processed by the local
bridging function, including bridge management
frames.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 6.6.1.1.3]]></reference>
                                </column>
                                <column name="dot1dTpPortInDiscards" oid="1.3.6.1.2.1.17.4.4.1.5" status="mandatory">
                                        <syntax>
                                                <type name="Counter" module=""/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[Count of valid frames received which were
discarded (i.e., filtered) by the Forwarding
Process.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 6.6.1.1.3]]></reference>
                                </column>
                        </row>
                </table>
                <table name="dot1dTpPortEntry" oid="1.3.6.1.2.1.17.4.4.1" status="mandatory">
                        <description><![CDATA[A list of information for each port of a
transparent bridge.]]></description>
                        <row name="dot1dTpPortEntry" oid="1.3.6.1.2.1.17.4.4.1" status="mandatory" create="false">
                                <linkage implied="false">
                                        <index module="BRIDGE-MIB" name="dot1dTpPort"/>
                                </linkage>
                                <description><![CDATA[A list of information for each port of a
transparent bridge.]]></description>
                                <column name="dot1dTpPort" oid="1.3.6.1.2.1.17.4.4.1.1" status="mandatory">
                                        <syntax>
                                                <typedef basetype="INTEGER">
                                                        <range min="1" max="65535"/>
                                                </typedef>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The port number of the port for which this entry
contains Transparent bridging management
information.]]></description>
                                </column>
                                <column name="dot1dTpPortMaxInfo" oid="1.3.6.1.2.1.17.4.4.1.2" status="mandatory">
                                        <syntax>
                                                <type name="INTEGER" module=""/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The maximum size of the INFO (non-MAC) field that
this port will receive or transmit.]]></description>
                                </column>
                                <column name="dot1dTpPortInFrames" oid="1.3.6.1.2.1.17.4.4.1.3" status="mandatory">
                                        <syntax>
                                                <type name="Counter" module=""/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The number of frames that have been received by
this port from its segment. Note that a frame
received on the interface corresponding to this
port is only counted by this object if and only if
it is for a protocol being processed by the local
bridging function, including bridge management
frames.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 6.6.1.1.3]]></reference>
                                </column>
                                <column name="dot1dTpPortOutFrames" oid="1.3.6.1.2.1.17.4.4.1.4" status="mandatory">
                                        <syntax>
                                                <type name="Counter" module=""/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[The number of frames that have been transmitted
by this port to its segment.  Note that a frame
transmitted on the interface corresponding to this
port is only counted by this object if and only if
it is for a protocol being processed by the local
bridging function, including bridge management
frames.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 6.6.1.1.3]]></reference>
                                </column>
                                <column name="dot1dTpPortInDiscards" oid="1.3.6.1.2.1.17.4.4.1.5" status="mandatory">
                                        <syntax>
                                                <type name="Counter" module=""/>
                                        </syntax>
                                        <access>readonly</access>
                                        <description><![CDATA[Count of valid frames received which were
discarded (i.e., filtered) by the Forwarding
Process.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 6.6.1.1.3]]></reference>
                                </column>
                        </row>
                </table>
                <node name="dot1dStatic" oid="1.3.6.1.2.1.17.5"/>
                <table name="dot1dStaticTable" oid="1.3.6.1.2.1.17.5.1" status="mandatory">
                        <description><![CDATA[A table containing filtering information
configured into the bridge by (local or network)
management specifying the set of ports to which
frames received from specific ports and containing
specific destination addresses are allowed to be
forwarded.  The value of zero in this table as the
port number from which frames with a specific
destination address are received, is used to
specify all ports for which there is no specific
entry in this table for that particular
destination address.  Entries are valid for
unicast and for group/broadcast addresses.]]></description>
                        <reference><![CDATA[IEEE 802.1D-1990: Section 6.7.2]]></reference>
                        <row name="dot1dStaticEntry" oid="1.3.6.1.2.1.17.5.1.1" status="mandatory" create="false">
                                <linkage implied="false">
                                        <index module="BRIDGE-MIB" name="dot1dStaticAddress"/>
                                        <index module="BRIDGE-MIB" name="dot1dStaticReceivePort"/>
                                </linkage>
                                <description><![CDATA[Filtering information configured into the bridge
by (local or network) management specifying the
set of ports to which frames received from a
specific port and containing a specific
destination address are allowed to be forwarded.]]></description>
                                <reference><![CDATA[IEEE 802.1D-1990: Section 6.7.2]]></reference>
                                <column name="dot1dStaticAddress" oid="1.3.6.1.2.1.17.5.1.1.1" status="mandatory">
                                        <syntax>
                                                <type name="MacAddress" module="BRIDGE-MIB"/>
                                        </syntax>
                                        <access>readwrite</access>
                                        <description><![CDATA[The destination MAC address in a frame to which
this entry's filtering information applies.  This
object can take the value of a unicast address, a
group address or the broadcast address.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 3.9.1, 3.9.2]]></reference>
                                </column>
                                <column name="dot1dStaticReceivePort" oid="1.3.6.1.2.1.17.5.1.1.2" status="mandatory">
                                        <syntax>
                                                <type name="INTEGER" module=""/>
                                        </syntax>
                                        <access>readwrite</access>
                                        <description><![CDATA[Either the value '0', or the port number of the
port from which a frame must be received in order
for this entry's filtering information to apply.
A value of zero indicates that this entry applies
on all ports of the bridge for which there is no
other applicable entry.]]></description>
                                </column>
                                <column name="dot1dStaticAllowedToGoTo" oid="1.3.6.1.2.1.17.5.1.1.3" status="mandatory">
                                        <syntax>
                                                <type name="OCTET STRING" module=""/>
                                        </syntax>
                                        <access>readwrite</access>
                                        <description><![CDATA[The set of ports to which frames received from a
specific port and destined for a specific MAC
address, are allowed to be forwarded.  Each octet
within the value of this object specifies a set of
eight ports, with the first octet specifying ports
1 through 8, the second octet specifying ports 9
through 16, etc.  Within each octet, the most
significant bit represents the lowest numbered
port, and the least significant bit represents the
highest numbered port.  Thus, each port of the
bridge is represented by a single bit within the
value of this object.  If that bit has a value of
'1' then that port is included in the set of
ports; the port is not included if its bit has a
value of '0'.  (Note that the setting of the bit
corresponding to the port from which a frame is
received is irrelevant.)  The default value of
this object is a string of ones of appropriate
length.]]></description>
                                </column>
                                <column name="dot1dStaticStatus" oid="1.3.6.1.2.1.17.5.1.1.4" status="mandatory">
                                        <syntax>
                                                <typedef basetype="INTEGER">
                                                        <namednumber name="other" number="1"/>
                                                        <namednumber name="invalid" number="2"/>
                                                        <namednumber name="permanent" number="3"/>
                                                        <namednumber name="deleteOnReset" number="4"/>
                                                        <namednumber name="deleteOnTimeout" number="5"/>
                                                </typedef>
                                        </syntax>
                                        <access>readwrite</access>
                                        <description><![CDATA[This object indicates the status of this entry.
The default value is permanent(3).

     other(1) - this entry is currently in use but
          the conditions under which it will
          remain so are different from each of the
          following values.
     invalid(2) - writing this value to the object
          removes the corresponding entry.
     permanent(3) - this entry is currently in use
          and will remain so after the next reset
          of the bridge.
     deleteOnReset(4) - this entry is currently in
          use and will remain so until the next
          reset of the bridge.
     deleteOnTimeout(5) - this entry is currently
          in use and will remain so until it is
          aged out.]]></description>
                                </column>
                        </row>
                </table>
                <table name="dot1dStaticEntry" oid="1.3.6.1.2.1.17.5.1.1" status="mandatory">
                        <description><![CDATA[Filtering information configured into the bridge
by (local or network) management specifying the
set of ports to which frames received from a
specific port and containing a specific
destination address are allowed to be forwarded.]]></description>
                        <reference><![CDATA[IEEE 802.1D-1990: Section 6.7.2]]></reference>
                        <row name="dot1dStaticEntry" oid="1.3.6.1.2.1.17.5.1.1" status="mandatory" create="false">
                                <linkage implied="false">
                                        <index module="BRIDGE-MIB" name="dot1dStaticAddress"/>
                                        <index module="BRIDGE-MIB" name="dot1dStaticReceivePort"/>
                                </linkage>
                                <description><![CDATA[Filtering information configured into the bridge
by (local or network) management specifying the
set of ports to which frames received from a
specific port and containing a specific
destination address are allowed to be forwarded.]]></description>
                                <reference><![CDATA[IEEE 802.1D-1990: Section 6.7.2]]></reference>
                                <column name="dot1dStaticAddress" oid="1.3.6.1.2.1.17.5.1.1.1" status="mandatory">
                                        <syntax>
                                                <type name="MacAddress" module="BRIDGE-MIB"/>
                                        </syntax>
                                        <access>readwrite</access>
                                        <description><![CDATA[The destination MAC address in a frame to which
this entry's filtering information applies.  This
object can take the value of a unicast address, a
group address or the broadcast address.]]></description>
                                        <reference><![CDATA[IEEE 802.1D-1990: Section 3.9.1, 3.9.2]]></reference>
                                </column>
                                <column name="dot1dStaticReceivePort" oid="1.3.6.1.2.1.17.5.1.1.2" status="mandatory">
                                        <syntax>
                                                <type name="INTEGER" module=""/>
                                        </syntax>
                                        <access>readwrite</access>
                                        <description><![CDATA[Either the value '0', or the port number of the
port from which a frame must be received in order
for this entry's filtering information to apply.
A value of zero indicates that this entry applies
on all ports of the bridge for which there is no
other applicable entry.]]></description>
                                </column>
                                <column name="dot1dStaticAllowedToGoTo" oid="1.3.6.1.2.1.17.5.1.1.3" status="mandatory">
                                        <syntax>
                                                <type name="OCTET STRING" module=""/>
                                        </syntax>
                                        <access>readwrite</access>
                                        <description><![CDATA[The set of ports to which frames received from a
specific port and destined for a specific MAC
address, are allowed to be forwarded.  Each octet
within the value of this object specifies a set of
eight ports, with the first octet specifying ports
1 through 8, the second octet specifying ports 9
through 16, etc.  Within each octet, the most
significant bit represents the lowest numbered
port, and the least significant bit represents the
highest numbered port.  Thus, each port of the
bridge is represented by a single bit within the
value of this object.  If that bit has a value of
'1' then that port is included in the set of
ports; the port is not included if its bit has a
value of '0'.  (Note that the setting of the bit
corresponding to the port from which a frame is
received is irrelevant.)  The default value of
this object is a string of ones of appropriate
length.]]></description>
                                </column>
                                <column name="dot1dStaticStatus" oid="1.3.6.1.2.1.17.5.1.1.4" status="mandatory">
                                        <syntax>
                                                <typedef basetype="INTEGER">
                                                        <namednumber name="other" number="1"/>
                                                        <namednumber name="invalid" number="2"/>
                                                        <namednumber name="permanent" number="3"/>
                                                        <namednumber name="deleteOnReset" number="4"/>
                                                        <namednumber name="deleteOnTimeout" number="5"/>
                                                </typedef>
                                        </syntax>
                                        <access>readwrite</access>
                                        <description><![CDATA[This object indicates the status of this entry.
The default value is permanent(3).

     other(1) - this entry is currently in use but
          the conditions under which it will
          remain so are different from each of the
          following values.
     invalid(2) - writing this value to the object
          removes the corresponding entry.
     permanent(3) - this entry is currently in use
          and will remain so after the next reset
          of the bridge.
     deleteOnReset(4) - this entry is currently in
          use and will remain so until the next
          reset of the bridge.
     deleteOnTimeout(5) - this entry is currently
          in use and will remain so until it is
          aged out.]]></description>
                                </column>
                        </row>