[AGENT++] GetNext behaviour for Non-Accessible OIDs
Marek Malowidzki
malowidz at wil.waw.pl
Thu Oct 23 12:31:12 CEST 2003
> Hi Rajesh,
>
> A GETNEXT should never return an error (in SNMPv2c/SNMPv3)
> in the error status field.
Except for endOfMibView, as I guess ;-).
Marek
More information about the AGENTPP
mailing list