Hi Dario,
If possible scale them to scalars and note the units
in the UNITS clause of the OBJECT-TYPE construct in
your MIB. If that is not feasible, I would recommend
coding the floating point into an OCTET STRING (with
appropriate DISPLAY-HINT). Others might prefer
using the Opaque type and BER encoding the float
(like NET-SNMP) but that approach is not widely used.
Best regards,
Frank
Dario maljur wrote:
> Hi.
>
> Maybe this is stupid question, but how do I manage floating point values?
>
> Through strings?
>
> _______________________________________________
> AGENTPP mailing list
> AGENTPP at agentpp.org
> http://lists.agentpp.org/mailman/listinfo/agentpp
--